TEST OF PURE HYDROGEN INFLOW SYSTEM DURING DISCHARGE CLEANING AND WORK REGIMES OF THE URAGAN-3M TORSATRON


G.P. Glazunov, E.D. Volkov, D.I. Baron, N.P. Ponomarenko
Institute of Plasma Physics, NSC KIPT, Kharkov, Ukraine


The tests of the pure hydrogen inflow system had been carried out during pulsed discharge cleaning and work regimes of the Uragan-3M torsatron. It had been shown that the inflow system provides required steady flows of hydrogen over the pressure range from 5x10-7 Torr to 10–4 Torr. The special cyclic procedures of membrane heating and pumping to provide the long life time of membranes, and required reliability and stable flow are described.

ИСПЫТАНИЕ СИСТЕМЫ НАПУСКА ЧИСТОГО ВОДОРОДА В РАБОЧЕМ РЕЖИМЕ И РЕЖИМЕ ЧИСТКИ ТОРСАТРОНА УРАГАН-3М


Г.П. Глазунов, Е.Д. Волков, Д.И. Барон, Н.П. Пономаренко


Проведены испытания системы напуска чистого водорода в рабочем режиме и в режиме чистки высокочастотными импульсами торсатрона Ураган-3М. Показано, что система напуска обеспечивает требуемые потоки в диапазоне давлений 5x10-7– 10-4 Торр. Для обеспечения требуемой надежности, продолжительности срока службы и стабильности потока водорода предлагается специальная процедура периодического нагрева и откачки диффузионных мембран.

ІСПИТ СИСТЕМИ НАПУСКУ ЧИСТОГО ВОДНЮ В РОБОЧОМУ РЕЖИМІ І РЕЖИМІ ЧИЩЕННЯ ТОРСАТРОНА УРАГАН-3М


Г.П. Глазунов, Є.Д. Волков, Д.І. Барон, М.П. Пономаренко


Проведено іспити системи напуску чистого водню в робочому режимі й у режимі чищення високочастотними імпульсами торсатрону Ураган-3М. Показано, що система напуску забезпечує необхідні потоки в діапазоні тисків 5x10-7 – 10-4 Торр. Для забезпечення необхідної надійності, тривалості терміну служби і стабільності потоку водню пропонується спеціальна процедура періодичного нагрівання і відкачки дифузійних мембран.